UL/FM 200PSI Resilient Wedge OS&Y Gate Valve - Flanged End Z41
Categories:
Compliance Credentials: Strictly certified to UL 260 and FM standards for high-hazard critical infrastructure
TEL:
UL/FM 200PSI Resilient Wedge OS&Y Gate Valve - Flanged End Z41
▏Product Description
Engineered by Ningjin APC Industries, the Model Z41 Resilient Wedge OS&Y Gate Valve is a flanged-end isolation valve fully conforming to ANSI / AWWA C515. Carrying premium FM Approval, UL, and CUL Listings, alongside lead-free certification under NSF / ANSI 61 & 372, this valve is built for rigid bidding approvals in fire protection and potable water networks.
It operates reliably under a maximum working pressure of 200 PSI (hydrostatically tested to 400 PSI in absolute accordance with FM 1120/1130 and UL 262) within a temperature range of 0~80°C (32~176°F). Featuring a straight-through, smooth-bottom ductile iron body (ASTM A536 65-45-12) encapsulated in EPDM, a pre-grooved SS304 stem for tamper switch installation, and electrostatic spray epoxy coating, Model Z41 ensures a bubble-tight seal and lifetime corrosion defense.
Review the complete technical specifications, material list, and dimensions for Model Z41 below:
▏Technical Features
| Parameter | Value |
|---|---|
| Flange Standard | ASME/ANSI B 16.1 Class 125 ASME/ANSI B 16.42 Class 150 BS EN 1092-2 PN 16 GB / T9113.1 |
| Face to Face Standard | ASME B16.10 |
| Sizes | 2", 2.5", 3", 4", 5", 6", 8", 10", 12" (FM UL) 14", 16" (FM) 18", 20", 24" |
| Approvals | FM, UL, CUL, NSF / ANSI 61 & NSF / ANSI 372 |
| Maximum Working Pressure | 200PSI |
| Maximum Testing Pressure | 400 PSI |
| Pressure Standard | Pressure conforms to FM 1120 / 1130, UL 262, ULC / ORD C262-92 |
| Working Temperature Range | 0~80°C / 32~176°F |
| Coating Details | Epoxy or Coating upon request |
| Design Feature | NPT plug on body with 2 operating nuts |
| Certification | Certified lead-free by NSF / ANSI 61 & NSF / ANSI 372 is available |
▏Valve Material List

| NO. | Name | Material | Standard |
|---|---|---|---|
| 1 | Body | Ductile Iron | ASTM A536 Grade 65-45-12 |
| 2 | Disc | Ductile Iron +EPDM | ASTM A536 Grade 65-45-12, ASTM D2000 |
| 3 | Connecting Part | C95400 | ASTM B148 |
| 4 | Sealing Pad | EPDM | ASTM D2000 |
| 5 | Stem | Stainless Steel 304 | ASTM A276 |
| 6 | Yoke | Ductile Iron | ASTM A536 Grade 65-45-12 |
| 7 | Bolt | Steel 1045 | ASTM A29 |
| 8 | Gland | Ductile Iron | ASTM A536 Grade 65-45-12 |
| 9 | Nut | Steel 1045 | ASTM A29 |
| 10 | Rotating Nut | C95400 | ASTM B148 |
| 11 | Handwheel | Steel 1045 | ASTM A29 |
| 12 | Lock Nut | Steel 1045 | ASTM A29 |
| 13 | Countersunk Head Bolt | Steel 1045 | ASTM A29 |
| 14 | Cylinder Pin | Stainless Steel 304 | ASTM A276 |
| 15 | Plug | C95400 | ASTM B148 |
▏Technical Features
| Size | L | H | øD |
|---|---|---|---|
| 2" | 178 | 313 | 152 |
| 2½" | 190 | 340 | 178 |
| 3" | 203 | 387 | 191 |
| 4" | 229 | 440 | 229 |
| 5" | 254 | 546 | 254 |
| 6" | 267 | 607 | 279 |
| 8" | 292 | 786 | 343 |
| 10" | 330 | 946 | 406 |
| 12" | 356 | 1110 | 483 |
▏FAQ
📌 Q1: Does Ningjin APC Model Z41 OS&Y gate valve hold the necessary FM/UL approvals and lead-free certifications for strict project compliance?
A: Yes, Model Z41 is fully certified for immediate municipal and commercial fire protection project submittals. It is FM Approved, UL Listed, and CUL Listed. Additionally, it carries certified lead-free compliance under NSF / ANSI 61 & NSF / ANSI 372, and is designed in strict accordance with the ANSI / AWWA C515 standard to guarantee seamless engineering approvals.
📌 Q2: What are the exact flange drilling standards and face-to-face dimensions for Model Z41 to verify piping blueprint compatibility?
A: Model Z41 is designed with standard face-to-face dimensions conforming strictly to ASME B16.10. To accommodate global piping specifications, its universal flanged ends adapt to multiple drilling connections: ASME/ANSI B 16.1 Class 125 ASME/ANSI B 16.42 Class 150 BS EN 1092-2 PN 16 GB / T9113.1 Size Range: Available from 2" to 24" (Sizes 2" to 12" are FM & UL listed; 14" to 16" are FM listed; 18" to 24" are non-listed). Refer to our dimensions table for precise L and H heights (e.g., 4" valve has an L of 229mm and H of 440mm).
📌 Q3: What pressure testing standards does Model Z41 undergo to pass on-site inspector checkouts?
A: Model Z41 is engineered to easily pass rigid hydrostatic testing prior to system commissioning. It supports a maximum working pressure of 200 PSI and undergoes rigorous maximum testing pressure of 400 PSI. This pressure boundary performance conforms fully to FM 1120 / 1130, UL 262, and ULC / ORD C262-92 testing guidelines.
📌 Q4: How is Model Z41 constructed to support tamper switch installation and resist on-site corrosion?
A: Model Z41 features a pre-grooved stem made of high-tensile Stainless Steel 304 (ASTM A276), enabling seamless, hassle-free installation of tamper switch signal indicators for electrical fire system linkage. To withstand buried or harsh outdoor environments, the ductile iron body (ASTM A536 Grade 65-45-12) is fully protected with an electrostatic spray epoxy coating on both interior and exterior surfaces.
📌 Q5: What are the available material grades and customized options for commercial procurement of Model Z41?
A: To guarantee long-service sealing life, Model Z41 features a premium material matrix: ductile iron wedge encapsulated in EPDM (ASTM D2000), and a high-grade C95400 Aluminum Bronze (ASTM B148) rotating nut to prevent operation wear. For custom specifications, we can supply alternative epoxy thickness or specialized coatings upon request. Contact our sales team with your size requirements to receive MTC (Material Test Certificates), factory-direct pricing, and exact lead times.
Product message
Related products
APC Industries
Mobile website
Add WeChat chat
CONTACT US
Add:No. 18 Taishan Road, Ningjin County, Shandong Province P.R.China
Mobile:+8618600252968
WeChat:cuiyuying01
E-Mail: